77EDh
CLAAS 77EDh – Claas Hyd A60 Claas Hydraulic Module: Power Supply of Valve 4 (Module A105-4) Too Low
Issue description
The power supply of valve 4 is below the minimum threshold of 8 V. This issue is associated with the electrodistributor module (A105-4).
Check the cause
Power supply voltage to valve 4
Electrodistributor module (A105-4) for proper operation
Repair steps
Verify the power supply voltage to valve 4
Use a multimeter to measure the voltage at the power supply connection of valve 4.
Inspect the electrodistributor module (A105-4)
Check for visible damage, loose connections, or signs of malfunction on the electrodistributor module (A105-4).
Parts you might need
(0)Get help to fix this fault by requesting a quote