CLAAS 77F1h – Claas Hyd A60 Claas Hydraulic Module: Fault in position sensor of valve 4 (internal) - probable open circuit

Issue description

The position sensor of valve 4 is faulty, likely due to an open circuit. The electrodistributor 4 returns to neutral, which may be related to the fault. The issue is associated with the electrodistributor module (A105-4).

Check the cause

  1. The position sensor of valve 4

  2. The electrodistributor 4

  3. The electrodistributor module (A105-4)

Repair steps

  1. Inspect

    Inspect the position sensor of valve 4 for signs of damage or disconnection.

  2. Test

    Test the electrodistributor 4 to confirm if it returns to neutral as described.

  3. Verify

    Verify the condition of the electrodistributor module (A105-4) for any faults or malfunctions.