CLAAS 77F2h – Claas Hyd A60 Claas Hydraulic Module: Valve 4 Drawer Does Not Return to Neutral Position

Issue description

The valve 4 drawer fails to return to its neutral position, either due to the return spring or the application of current. The cause is identified as the electrodistributor 4 returning to neutral. The affected component is the electrodistributor module (A105-4).

Check the cause

  1. The electrodistributor 4

  2. The electrodistributor module (A105-4)

Repair steps

  1. Inspect

    Inspect the electrodistributor 4 for signs of mechanical or electrical failure.

  2. Test

    Test the electrodistributor module (A105-4) for proper operation according to the service manual.

  3. Replace

    If the electrodistributor 4 or the electrodistributor module (A105-4) is found to be faulty, replace the component.