Id7827h / 7827h

CLAAS Id7827h / 7827h – HYD (A60) / A060 - Hydraulic Control Module: CAN communication failure

Issue description

The HYD module no longer transmits any messages on the Hydraulic CAN bus due to a number of CAN frame errors too high on the Hydraulic CAN bus

Applies to these machines

  • Axion 800
  • Axion 810
  • Axion 850
  • Axion 920
  • Axion 930
  • Axion 950
  • Axion 960
  • Arion 410
  • Arion 430
  • Arion 510
  • Arion 530
  • Arion 550
  • Arion 620
  • Arion 640
  • Arion 650

Check the cause

  1. Inspect the physical integrity of the Hydraulic CAN Bus network

  2. Check the connectors and continuity of the harnesses linking the HYD (A60) module to the CAN bus

  3. Check for any short-circuits or open circuits on the CAN lines

  4. Check the sources of energy to the module, including all relevant fuses, power supply lines, and ground connections

  5. Check the component's operating conditions (e.g., pressure, temperature, mechanical seizing)

Repair steps

  1. Visual & Physical Inspection

    Locate the HYD (A60) module and inspect its main wiring harness connector. Look for pushed-out pins, corrosion, or moisture ingress.

  2. Wiring Test

    Using a multimeter, verify that the HYD module is receiving proper 12V power and has a solid ground.

  3. CAN Bus Test

    Measure the resistance across the Hydraulic CAN bus (with batteries disconnected) to ensure the terminating resistors are intact (typically ~60 ohms). Check for shorts to ground or shorts to power on the CAN High and CAN Low lines.

  4. Software/Calibration Check

    Check the compatibility of the program versions, settings, and calibration of the module using the CLAAS Diagnostic System (CDS).

  5. Module Replacement

    If the wiring, power, ground, and CAN bus integrity are all confirmed to be good, but the module still fails to transmit messages, the HYD (A60) module itself has failed internally and must be replaced or sent out for repair.

Parts you might need

(1)
  • Hydraulic Control Module (HYD A60 / A060)

    A060 447 01 40

    Because this is a primary control unit, a replacement module will likely require programming/calibration via the CLAAS Diagnostic System (CDS) to match the specific tractor's configuration. Alternatively, specialized ECU repair centers offer rebuild services for this specific module.

Get help to fix this fault by requesting a quote

Browse other CLAAS codes