Id7879h / 7879h

CLAAS Id7879h / 7879h – MFT (A30): Internal temperature sensor of the terminal out of service

Issue description

The system detects that the temperature sensor located inside the display terminal has failed or stopped communicating.

Applies to these machines

  • Axion 800
  • Axion 810
  • Axion 820
  • Axion 840
  • Axion 850
  • Axion 920-950
  • Arion 510-640
  • Arion 500/600 series
  • Lexion
  • Jaguar

Check the cause

  1. Check the CEBIS terminal module MFT (A30) to verify if the terminal is otherwise functioning normally or if it is physically overheating

  2. Check cab climate control to ensure it is functioning properly and not blowing excessive heat directly onto the back of the monitor

  3. Cycle the battery power to reboot/reset the system and see if internal sensor communication restores

Repair steps

  1. Turn off the machine and disconnect the main battery power

    This prevents electrical shorts before beginning the repair.

  2. Locate the CEBIS terminal (MFT A30)

    The terminal is located on the right-hand armrest or cab rail.

  3. Disconnect wiring harnesses

    Carefully disconnect the main wiring harness and any camera/ISOBUS connectors from the rear of the unit.

  4. Unbolt the terminal

    Unbolt the terminal from its mounting bracket.

  5. Repair or replace the terminal

    Option A (Repair): Send the unit to an electronics specialist who can open the casing and replace the faulty internal surface-mount temperature sensor or repair the board. Option B (Replace): Mount the new or remanufactured CEBIS terminal to the bracket.

  6. Reconnect wiring

    Reconnect all wiring harnesses securely.

  7. Restore power

    Reconnect battery power and turn on the ignition.

  8. Calibrate or flash the unit

    A replacement terminal may require a CLAAS dealer to perform a software calibration or flash the unit using the METADIAG diagnostic tool to match your specific machine's configuration.

Parts you might need

(8)
  • CEBIS Terminal Display / MFT A30 Module

    00172600

    Also known as 0017260.0. Verify exact part number printed on sticker on back of current terminal.

  • CEBIS Terminal Display / MFT A30 Module

    00178340

    Also known as 0017834.0 / 0017834.2. Verify exact part number printed on sticker on back of current terminal.

  • CEBIS Terminal Display / MFT A30 Module

    0015273.2

    Common remanufactured part number. Verify exact part number printed on sticker on back of current terminal.

  • CEBIS Terminal Display / MFT A30 Module

    0015011.1

    Verify exact part number printed on sticker on back of current terminal.

  • CEBIS Terminal Display / MFT A30 Module

    0015273.0

    Verify exact part number printed on sticker on back of current terminal.

  • CEBIS Terminal Display / MFT A30 Module

    0015274.0

    Verify exact part number printed on sticker on back of current terminal.

  • CEBIS Terminal Display / MFT A30 Module

    0016048.2

    Verify exact part number printed on sticker on back of current terminal.

  • CEBIS Terminal Display / MFT A30 Module

    0016049.2

    Verify exact part number printed on sticker on back of current terminal.

Get help to fix this fault by requesting a quote

Browse other CLAAS codes