Id7886h / 7886h

CLAAS Id7886h / 7886h – EXT (A62) - External function module: Communication failure on the ISO CAN bus network

Issue description

The EXT module no longer transmits any messages on the ISO CAN bus due to a number of CAN frame errors too high on the ISO CAN bus.

Applies to these machines

  • Axion 800
  • Axion 810
  • Axion 850
  • Axion 920
  • Axion 950
  • Arion 510
  • Arion 530
  • Arion 540
  • Arion 550
  • Arion 620
  • Arion 640
  • Arion 650

Check the cause

  1. Inspect the physical wiring harness for the ISO CAN bus.

  2. Verify the external function module EXT (A62) is receiving power and functioning.

  3. Check the sources of energy to the EXT module, including all relevant fuses, power supply lines, and ground connections.

  4. Check the connectors and continuity of the harnesses linking the EXT module to the rest of the CAN network.

  5. Test the ISO CAN bus lines for short-circuits to 12V, short-circuits to ground, or open circuits.

Repair steps

  1. Document and Analyze

    Note all error codes present on the tractor's Cebis terminal or diagnostic tool. Analyze the interaction between these codes, as a voltage or ground issue can generate multiple CAN bus errors simultaneously.

  2. Inspect Wiring and Connectors

    Locate the EXT (A62) module. Disconnect its harness and inspect the pins for corrosion, pushed-out pins, or moisture.

  3. Test the ISO CAN Bus

    Using a multimeter, test the ISO CAN bus wiring for proper resistance (typically 60 ohms across CAN High and CAN Low with batteries disconnected) and ensure there is no short to ground or short to power.

  4. Repair Wiring

    If a short, open circuit, or damaged connector is found on the ISO CAN bus network, repair or replace the affected harness section.

  5. Software/Calibration Check

    Check the compatibility of the program versions, settings, and calibration of the EXT module.

  6. Clear and Retest

    Clear all error codes from the system. Cycle the ignition and operate the tractor to see if the anomaly returns.

  7. Replace Module

    If the wiring, power, and grounds are all intact and the error persists, the EXT (A62) module has suffered an internal failure and must be replaced.

Parts you might need

(6)
  • UBM Type 7 V4 EXT module (External function module)

    0021704790

    Often requires dealer-level software calibration (CLAAS Diagnostic System / CDS) to configure the module to the specific tractor's options upon installation.

  • UBM Type 7 V4 EXT module (External function module)

    21704790

    Often requires dealer-level software calibration (CLAAS Diagnostic System / CDS) to configure the module to the specific tractor's options upon installation.

  • UBM Type 7 V4 EXT module (External function module)

    0021632160

    Often requires dealer-level software calibration (CLAAS Diagnostic System / CDS) to configure the module to the specific tractor's options upon installation.

  • UBM Type 7 V4 EXT module (External function module)

    21632160

    Often requires dealer-level software calibration (CLAAS Diagnostic System / CDS) to configure the module to the specific tractor's options upon installation.

  • UBM Type 7 V4 EXT module (External function module)

    AK0537560

    Often requires dealer-level software calibration (CLAAS Diagnostic System / CDS) to configure the module to the specific tractor's options upon installation.

  • ISO CAN bus repair pigtail or CLAAS specific harness section

    Required if the issue is isolated to the wiring depending on where the break is located.

Get help to fix this fault by requesting a quote