CLAAS Id788Ah / 788Ah – EXT (A62): EXT external function module has not received actual speed information
Issue description
The EXT external function module has not received actual speed information for more than 5 seconds via the vehicle's CAN BUS network. Specifically, the system detects that the actual speed information is not available on the 7-pin ISO connector.
Applies to these machines
13 machines- Axion 800
- Axion 810
- Axion 850
- Axion 920
- Axion 950
- Arion 410
- Arion 430
- Arion 510
- Arion 530
- Arion 550
- Arion 620
- Arion 640
- Arion 650
Check the cause
Check the 7-pin ISO connector: Verify that the actual speed information is present at the connector and that the plug is not damaged, corroded, or disconnected.
Check the CLAAS vehicle CAN bus network: Inspect the wiring harness for short-circuits (to 12V or ground) or open circuits.
Check the BDG (A103) module: This is the CAN network communication module responsible for relaying information across the bus.
Check the DBD (A101) module: This is the instrument panel/dashboard module, which often processes and transmits speed data.
Check the EXT (A62) module: Ensure the external function module is receiving power and ground.
Repair steps
Visual & Physical Inspection
Inspect the 7-pin ISO connector at the rear of the tractor. Clean the contacts and ensure the implement/radar speed signal wiring is intact.
Wiring Continuity Test
Using a multimeter, check the resistance and continuity of the CAN bus lines between the EXT (A62), BDG (A103), and DBD (A101) modules.
Power & Ground Check
Check the sources of energy (fuses, supply voltage, and ground connections) for the EXT, BDG, and DBD modules.
Software/Calibration Check
Connect the CLAAS Diagnostic System (CDS) to verify the compatibility of program versions and settings between the dashboard (DBD) and the external function module (EXT).
Component Replacement
If the wiring, fuses, and software are all verified to be in working order, replace the faulty component (starting with the 7-pin connector/wiring, followed by the EXT or BDG module if CAN communication is internally failing).
Parts you might need
(4)7-Pin ISO Connector (Plug/Socket)
CLAAS 605 006 008Standard 7-pin 24V/12V ISO connector (ISO 1185 / ISO 1724).
EXT (A62) External Function Module
Must be ordered via dealer using the tractor's specific configuration (CCN A062).
BDG (A103) CAN Network Communication Module
DBD (A101) Dashboard / Instrument Panel Module
CCN A101
Get help to fix this fault by requesting a quote