CLAAS 788Bh: EXT External Function Module Not Receiving Theoretical Speed Information
Issue description
The EXT external function module is not receiving theoretical speed information from the 7-pin ISO connector via the BUS CAN. This condition has persisted for more than 5 seconds, indicating a potential issue with the data transmission or the source of the theoretical speed signal.
Check the cause
The connection and integrity of the 7-pin ISO connector
The BUS CAN communication between the EXT external function module and the source of the theoretical speed information
The signal source providing theoretical speed information to the 7-pin ISO connector
Repair steps
Inspect
Check the 7-pin ISO connector for damage, corrosion, or loose connections.
Test
Verify the BUS CAN communication using a diagnostic tool to ensure proper signal transmission.
Validate
Confirm that the component providing the theoretical speed information is functioning correctly and sending the signal to the 7-pin ISO connector.
Parts you might need
(0)Get help to fix this fault by requesting a quote