788Bh

CLAAS 788Bh: EXT External Function Module Not Receiving Theoretical Speed Information

Issue description

The EXT external function module is not receiving theoretical speed information from the 7-pin ISO connector via the BUS CAN. This condition has persisted for more than 5 seconds, indicating a potential issue with the data transmission or the source of the theoretical speed signal.

Check the cause

  1. The connection and integrity of the 7-pin ISO connector

  2. The BUS CAN communication between the EXT external function module and the source of the theoretical speed information

  3. The signal source providing theoretical speed information to the 7-pin ISO connector

Repair steps

  1. Inspect

    Check the 7-pin ISO connector for damage, corrosion, or loose connections.

  2. Test

    Verify the BUS CAN communication using a diagnostic tool to ensure proper signal transmission.

  3. Validate

    Confirm that the component providing the theoretical speed information is functioning correctly and sending the signal to the 7-pin ISO connector.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes