CLAAS 788Dh: Rear Lifting Status Information Not Received
Issue description
The EXT external function module is not receiving rear lifting status information for more than 5 seconds via the BUS CAN. Additionally, lifting high position information is not available on the 7-pin ISO connector.
Check the cause
The connection of the 7-pin ISO connector
The BUS CAN communication between the EXT external function module and the relevant system
The signal transmission path for rear lifting status information
Repair steps
Inspect
Check the 7-pin ISO connector for proper connection and physical damage.
Test
Verify the BUS CAN communication between the EXT external function module and the system providing the rear lifting status information.
Check
Ensure that the signal path for rear lifting status information is intact and functioning as intended.
Parts you might need
(0)Get help to fix this fault by requesting a quote