CLAAS Id7891h / 7891h – EXT (A62) - External Function Module: Position Lights Communication or Signal Failure
Issue description
The external function module has received no information from the position lights, or it has received an invalid signal from the position lights for more than 5 seconds over the CAN bus. As a result, the position light information is not available on the rear ISO 7-pin implement connector.
Applies to these machines
8 machines- CLAAS Axion 800 Series
- CLAAS Axion 810
- CLAAS Axion 850
- CLAAS Axion 900 Series
- CLAAS Axion 920
- CLAAS Axion 950
- CLAAS Arion 600 Series
- CLAAS Arion 640
Check the cause
Check the ISO 7-pin connector for physical presence of the position light signal, corrosion, pushed-out terminals, or physical damage
Check the CLAAS vehicle CAN bus network lines for proper voltage and resistance to ensure messages can be transmitted
Check the BDG (A103) Module to ensure it is communicating properly on the CAN bus network
Check the EXT (A62) Module power supply, ground, and fuses
Inspect the wiring harness for short-circuits or open circuits between the lighting circuit, the EXT module, and the ISO 7-pin connector
Repair steps
Visual Inspection
Start at the rear of the tractor. Open the flap of the ISO 7-pin connector and clean out any dirt or debris. Look for green corrosion on the terminals.
Test the Output
Turn on the tractor's position lights. Use a multimeter to check for 12V at the position light pins on the ISO 7-pin connector.
Harness Continuity Test
If there is no voltage at the connector, trace the wiring harness back from the ISO 7-pin connector to the EXT (A62) module. Repair any broken wires or chafed insulation causing a short to ground.
Module Power/Ground Check
Test the power and ground inputs at the EXT (A62) and BDG (A103) modules. Replace any blown fuses and clean ground eyelets.
Software/Calibration
If the wiring and connectors are perfectly intact, check the compatibility of the program versions. The EXT (A62) or BDG (A103) module may need a software re-flash by a CLAAS dealer.
Module Replacement
If all wiring, CAN bus resistance (typically 60 ohms across CAN High and CAN Low), and software checks pass, replace the faulty EXT (A62) module.
Parts you might need
(3)External Function Module (EXT - A62)
Requires dealer programming upon installation
CAN Bus Network Communication Module (BDG - A103)
ISO 7-Pin Trailer/Implement Connector
Generic agricultural standard (ISO 1185 / ISO 3732 type depending on exact spec)
Get help to fix this fault by requesting a quote