7893h

CLAAS 7893h: Stop Light Signal Issue on Right Side

Issue description

The external function module EXT is not receiving valid information from the right stop light or is not receiving any information from the stop lights for more than 5 seconds via the Bus CAN. The right stop light information is not available on the 7 pin ISO connector.

Check the cause

  1. The connection of the right stop light to the 7 pin ISO connector

  2. The wiring between the right stop light and the external function module EXT

  3. The functionality of the right stop light itself

Repair steps

  1. Inspect

    Check the connection of the right stop light to the 7 pin ISO connector for any loose, damaged, or corroded pins.

  2. Test

    Verify the wiring between the right stop light and the external function module EXT for continuity and proper insulation.

  3. Test

    Check the functionality of the right stop light by activating the brake and observing if it illuminates correctly.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes