Id78A6h / 78A6h

CLAAS Id78A6h / 78A6h – EXT (A62) - External Function Module: The CSM sequence is interrupted. The CSM sequence is interrupted after pressing one of the external commands

Issue description

Fault code Id78A6h indicates an operational interruption rather than a hardware failure. It is logged when an active automated sequence (CLAAS Sequence Management) is canceled because the operator manually pressed an external command button (such as a hydraulic or linkage control on the CMOTION joystick or fenders) while the sequence was running.

Applies to these machines

  • Axion 810
  • Axion 830
  • Axion 850
  • Axion 920
  • Axion 930
  • Axion 940
  • Axion 950
  • Arion 510
  • Arion 530
  • Arion 550
  • Arion 610
  • Arion 630
  • Arion 640
  • Arion 650
  • Arion 660

Check the cause

  1. Confirm with the operator if they manually pressed an external command button (e.g., spool valve, linkage, or PTO switch) while a headland sequence was actively playing

  2. If the operator did not press a button, check the external command switches (such as fender buttons for PTO/linkage) and the CMOTION joystick buttons for sticking, dirt ingress, or short circuits that might be sending a false interrupt signal

  3. Verify the operation of the S177 'CLAAS Sequence Management' switch on the right-hand console

Repair steps

  1. Clear the Code

    Acknowledge and clear the code from the CEBIS or CIS+ display.

  2. Operator Instruction

    Instruct the operator to let the CSM sequence finish its recorded steps before manually intervening with external hydraulic or linkage controls.

  3. Restart Sequence

    Reactivate the CSM sequence using the F buttons or CMOTION joystick to ensure it completes without interruption.

  4. Harness/Switch Repair

    If the sequence continues to interrupt without operator input, use a multimeter to test the continuity of the external command switches and the S177 CSM switch. Clean or replace any sticking switches.

Parts you might need

(2)
  • CSM ON/OFF Switch (Component S177)

    Specific OEM part numbers vary heavily by exact cab configuration and VIN

  • External Function Module (Component EXT A62)

    Specific OEM part numbers vary heavily by exact cab configuration and VIN

Get help to fix this fault by requesting a quote