CLAAS 78A8h – EXT (A62): CSM Sequence Not Started Due to Low Speed
Issue description
The CLAAS Sequence Management (CSM) system has been interrupted or cannot begin because the tractor's ground speed is below the required minimum threshold of 1.5 km/h. This prevents the sequence from initiating properly to avoid accidental activation when stationary. If the tractor is moving faster than 1.5 km/h and the fault persists, it indicates a failure in the components that measure and communicate the vehicle's speed over the CAN bus network to the EXT module.
Applies to these machines
4 machines- Arion 640-510
- Arion 500/600 series with CEBIS or CIS+
- Axion 850-810
- Axion 800/900 series with CEBIS or CIS+
Check the cause
Confirm the tractor is actually moving at a speed greater than 1.5 km/h when attempting to start the CSM sequence
Check for other active fault codes, specifically 78D8h (CAN 'Speed' message not received) or AD4E (inconsistent vehicle ground speed)
Inspect the wiring harness and connectors for the wheel speed sensor(s), radar sensor, and the EXT (A62) module for damage, corrosion, or loose connections
Check CAN bus connectors located under the cab floor and behind the dashboard for moisture ingress
Test the speed sensor resistance (power off) and AC voltage generation (power on, wheel rotating)
Perform CAN bus network diagnostics, including termination resistor check (should be ~60 Ohms) and voltage checks (CAN High 2.5-3.0V, CAN Low 2.0-2.5V)
Repair steps
Address simple causes and related codes
Ensure the tractor is moving above 1.5 km/h. If related fault codes like 78D8h or AD4E are present, diagnose and resolve them first as they directly impact the speed signal.
Inspect and clean connections
Disconnect, clean the contacts, and ensure a secure connection for the speed sensor, dashboard module (A101), and EXT module (A62).
Test and replace speed sensor
Perform resistance and AC voltage tests on the speed sensor. If the sensor fails to generate an AC voltage that increases with speed, or if resistance is out of spec, replace it.
Verify CAN bus integrity
Perform CAN bus resistance and voltage checks. Fix any termination or wiring issues. If voltages are incorrect, isolate modules one by one to find the source pulling the bus voltage down.
Calibrate dashboard
If applicable to the model, resolve incorrect speed information by calibrating the dashboard (instrument panel) using the operator's manual or the CLAAS Diagnostic System (CDS).
Diagnose control modules
If the sensor and CAN bus wiring are good, use the CLAAS Diagnostic System to test the Dashboard (DBD A101) and EXT (A62) modules, replacing them if necessary.
Parts you might need
(5)- Speed Sensor0000118100
Also listed as 011810.0, 0118100, 1821995.0. Verify fitment by serial number.
- Speed Sensor0000117602
Listed for combine harvesters, but may have cross-compatibility.
Speed Sensor
000676835Listed for combine harvesters.
- Speed Sensor0006040150
Verify fitment by serial number.
EXT External Functions Module (A62)
Requires sourcing through a CLAAS dealer with the correct part number for the specific machine.