Id78ACh / 78ACh

CLAAS Id78ACh / 78ACh – EXT (A62): CSM Communication Failure / No Input Message Received

Issue description

Communication problem involving the Claas Sequence Management (CSM) system. A communication failure occurred between one of the functions controlled by the CSM and the external function module because no input message was received from the expected component.

Applies to these machines

  • CLAAS Axion 800 Series
  • CLAAS Axion 900 Series
  • CLAAS Arion 500 / 600 Series

Check the cause

  1. Verify the status and CAN bus communication of the hydraulic module (HYD A60)

  2. Inspect the wiring harness connecting the HYD (A60) module, the CSM valves, and the EXT (A62) module

  3. Inspect the specific hydraulic valve controlled by the CSM for electrical or mechanical faults

  4. Verify the external function module (EXT A62) itself is online and communicating on the CLAAS vehicle CAN bus

Repair steps

  1. Visual & Harness Inspection

    Inspect the wiring harness between the EXT (A62) module, the HYD (A60) module, and the CSM hydraulic valves. Look for chafed wires, pinched cables, or loose connector pins.

  2. Electrical Testing

    Use a multimeter to check for short-circuits (to 12V or to ground) or open circuits on the CAN bus lines and the valve control circuits.

  3. Power & Ground Verification

    Check the sources of energy for both the EXT (A62) and HYD (A60) modules. Verify that all related fuses are intact and that the modules have a solid ground connection.

  4. Component Resistance & Mechanical Check

    Test the resistance of the CSM valve solenoid. Check the valve's operating conditions to ensure the spool is not mechanically seized.

  5. Software & Calibration

    Check the compatibility of the program versions between the EXT and HYD modules. Recalibrate the CSM system if a software glitch is suspected.

  6. Component Replacement

    If the wiring, power, and grounds are perfectly intact but the communication failure persists, replace the faulty component (the CSM valve, the HYD A60 module, or the EXT A62 module).

Parts you might need

(3)
  • EXT Module (External Functions Module)

    A62

    Requires dealer programming/calibration upon installation to sync with the CLAAS vehicle CAN bus.

  • HYD Module (Hydraulic Module)

    A60

    Controls hydraulic valve actuation; requires software matching with the EXT and CEBIS modules.

  • CSM Hydraulic Valve / Solenoid

    Check the specific remote valve block that the CSM was attempting to control when the fault was logged.

Get help to fix this fault by requesting a quote