CLAAS 78B7h: Communication loss between TR2 (A57-2) and EXT (A62) module 2
Issue description
The TR2 (A57-2) transmission module has detected a communication loss with the external function module EXT (A62) during a CSM sequence. The differential lock was disconnected during this event.
Check the cause
Connections between TR2 (A57-2) and EXT (A62) modules
Cabling and wiring between TR2 (A57-2) and EXT (A62) modules
Power supply to TR2 (A57-2) and EXT (A62) modules
Repair steps
Inspect connections
Check all physical connections between TR2 (A57-2) and EXT (A62) modules for looseness, damage, or corrosion.
Test cabling
Verify the integrity of the cabling between TR2 (A57-2) and EXT (A62) modules using a multimeter or continuity tester.
Check power supply
Ensure that both TR2 (A57-2) and EXT (A62) modules are receiving the correct voltage and that there are no power interruptions.
Parts you might need