CLAAS 78BDh: Communication loss between Transmission module TR3 (A57-3) and External function module EXT (A62)
Issue description
The Transmission module TR3 (A57-3) has detected a communication loss with the External function module EXT (A62) during a CSM sequence. This indicates a failure in the communication link between these two modules.
Check the cause
Connections between Transmission module TR3 (A57-3) and External function module EXT (A62)
Cabling or wiring between Transmission module TR3 (A57-3) and External function module EXT (A62)
Power supply to Transmission module TR3 (A57-3) and External function module EXT (A62)
Repair steps
Inspect
Inspect the connections and cabling between Transmission module TR3 (A57-3) and External function module EXT (A62) for damage, looseness, or corrosion.
Test
Test the power supply to both Transmission module TR3 (A57-3) and External function module EXT (A62) to ensure they are receiving the correct voltage.
Reconnect
If any connections are loose or damaged, reconnect or replace them as necessary.
Parts you might need
(0)Get help to fix this fault by requesting a quote