Id78C5h / 78C5h (861)

CLAAS Id78C5h / 78C5h (861) – SFA (A102) - Front suspended axle module: Communication loss with the external function module EXT (A62) during a CSM sequence

Issue description

The front suspended axle module SFA (A102) has detected a communication loss with the external function module EXT (A62) during a CLAAS Sequence Management (CSM) sequence. As a safety and operational precaution, the front suspended axle is disconnected when this communication loss occurs.

Applies to these machines

  • CLAAS Axion 800 series
  • CLAAS Axion 810
  • CLAAS Axion 850
  • CLAAS Axion 900 series
  • CLAAS Axion 920
  • CLAAS Axion 950
  • CLAAS Arion 500 series
  • CLAAS Arion 600 series
  • CLAAS Arion 510
  • CLAAS Arion 530
  • CLAAS Arion 540
  • CLAAS Arion 550
  • CLAAS Arion 620
  • CLAAS Arion 640
  • CLAAS Arion 650

Check the cause

  1. Check the SFA (A102) suspended axle module

  2. Check the external function module EXT (A62)

  3. Check the CLAAS vehicle CAN bus network for communication integrity

  4. Check the connectors and the continuity of the harnesses linking the SFA and EXT components

  5. Check for any short-circuits or open circuits in the wiring

  6. Check the sources of energy for both modules (fuses, power supply, and ground)

  7. Check the compatibility of program versions, settings, and calibration between the modules

Repair steps

  1. Document

    Note all error codes currently present on the tractor.

  2. Analyze

    Identify the nature of each error code and analyze the interaction between them, as a CAN bus error or power failure can generate multiple cascading codes. Identify if the communication loss is the root anomaly.

  3. Inspect Wiring

    Perform tests and measurements on the CAN bus network, specifically checking the harness continuity, power (12V), and ground connections to both the A102 (SFA) and A62 (EXT) modules.

  4. Replace Component

    If the wiring, fuses, and power supplies are intact and functioning correctly, replace the faulty component (either the SFA or EXT module) causing the communication drop.

  5. Clear and Retest

    Clear all error codes from the system. Test the tractor by relaunching a CSM sequence to ensure the anomaly does not appear again and that the front suspended axle remains active.

Parts you might need

(7)
  • UBM TYPE 7 V4 EXT MODULE

    21704790

    Used across various Arion (e.g., 540-510) and Axion models.

  • UBM TYPE 7 V4 EXT MODULE

    0021704790

    Used across various Arion (e.g., 540-510) and Axion models.

  • UBM TYPE 7 V4 EXT MODULE

    21632160

    Used across various Arion (e.g., 540-510) and Axion models.

  • UBM TYPE 7 V4 EXT MODULE

    0021632160

    Used across various Arion (e.g., 540-510) and Axion models.

  • UBM TYPE 7 V4 EXT MODULE

    2170477.0

    Used across various Arion (e.g., 540-510) and Axion models.

  • UBM TYPE 7 V4 EXT MODULE

    AK0537560

    Used across various Arion (e.g., 540-510) and Axion models.

  • SFA Controller / Front Axle Suspension Module

Get help to fix this fault by requesting a quote

Browse other CLAAS codes