Id78D0h / 78D0h (872)

CLAAS Id78D0h / 78D0h (872) – REH (A58) - Rear Lifting Module: Communication loss between lifting module REH (A58) and external function module EXT (A62)

Issue description

The lifting module REH (A58) has detected a communication loss with the external function module EXT (A62) during a CSM (CLAAS Sequence Management) sequence. The rear lifting function is disconnected and becomes inoperative. The tractor will attempt to initialize after 20 seconds and relaunch the sequence.

Applies to these machines

  • CLAAS Axion 800 Series (810, 850)
  • CLAAS Axion 900 Series (920, 950)
  • CLAAS Arion 600 Series (610, 630, 640)
  • CLAAS Arion 500 Series (510)

Check the cause

  1. Verify the status of the lifting module REH (A58) and the external function module EXT (A62)

  2. Check the connectors and the continuity of the wiring harnesses linking the REH (A58) and EXT (A62) modules on the CLAAS vehicle CAN bus

  3. Check for any short-circuits or open circuits in the communication lines

  4. Check the sources of energy (fuses, power supply, and ground) for both the A58 and A62 modules

  5. Check the compatibility of program versions, settings, and calibration between the modules

Repair steps

  1. System Reset

    Wait to see if the sequence relaunches after the 20-second auto-initialization. If nothing happens, manually reset the CSM (CLAAS Sequence Management).

  2. Visual Inspection

    Inspect the wiring harness and connectors at both the REH (A58) module (typically located under the right-hand console) and the EXT (A62) module. Look for pushed pins, corrosion, or wire chafing.

  3. Electrical Testing

    Using a multimeter, test the CAN bus communication lines between the REH and EXT modules for continuity, short-to-ground, and short-to-power.

  4. Verify Power/Ground

    Ensure both modules are receiving stable 12V power and have a clean ground connection.

  5. Repair Wiring

    Repair any damaged wiring or replace faulty connector pins discovered during testing.

  6. Module Replacement

    If the wiring, power, and grounds are completely intact and the CSM reset does not restore communication, one of the modules (REH or EXT) has suffered an internal failure and must be replaced. (Note: Replacement modules will require dealer programming/calibration to match the tractor's software version).

Parts you might need

(2)
  • Rear Lifting Module (REH) - Component A58

    Always provide the dealer with the tractor's VIN/Serial Number to ensure the correct hardware revision is ordered, as CAN bus modules are version-specific.

  • External Functions Module (EXT) - Component A62

    Always provide the dealer with the tractor's VIN/Serial Number to ensure the correct hardware revision is ordered, as CAN bus modules are version-specific.