A03Ch

CLAAS A03Ch: Fault in 2 valve Supply

Issue description

The fault code indicates an issue with the supply of the 2 valve. The system checks the voltage delivered by the alternator and battery. If the error reappears after clearing, the 2 valve may need to be replaced.

Check the cause

  1. Voltage delivered by the alternator

  2. Battery voltage

  3. Condition of the 2 valve

Repair steps

  1. Check

    Verify the voltage delivered by the alternator and battery.

  2. Clear

    Clear the error code.

  3. Observe

    Monitor the system to see if the error reappears.

  4. Replace

    If the error reappears, replace the 2 valve.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes