CLAAS A059h: Fault Code A059h - Valve 3

Issue description

The system has detected an internal calculation error with a value out of range. The system attempts to clear the error and return Valve 3 to neutral. If the error reoccurs, the Valve 3 may need to be replaced.

Check the cause

  1. The status of Valve 3 and its operation during system startup

  2. The presence of recurring error messages after clearing the fault

  3. The integrity of the system's internal calculation process

Repair steps

  1. Clear the error

    Follow the system's procedure to clear the error and observe if Valve 3 returns to neutral.

  2. Monitor for recurrence

    Check if the error reappears after clearing it. If it does, proceed to the next step.

  3. Replace Valve 3

    If the error persists, replace Valve 3 as indicated in the system response.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes