CLAAS A08Ch: Valve 4 Returns to Neutral After Memory Save Error
Issue description
A fault occurs when saving memory, causing Valve 4 to return to neutral. The system requires the ignition to be turned off and a waiting period of at least 20 seconds in the EEPROM. If the error reoccurs, Valve 4 may need to be replaced.
Check the cause
Valve 4 operation after memory save
Ignition cycle and EEPROM timing
Repetition of the error after reset
Repair steps
Turn the ignition off
Ensure the ignition is fully turned off.
Wait for at least 20 seconds
Allow the system to complete the EEPROM process.
Restart the system
Turn the ignition back on and check if the error reoccurs.
Replace Valve 4
If the error appears again, replace Valve 4 as indicated in the source.
Parts you might need
(0)Get help to fix this fault by requesting a quote