Issue description
The system has detected that the command for valve 5 is impossible to execute. Valve 5 is returning to a neutral position. The error can be cleared, but if it reoccurs, the 5 valve may need to be replaced.
Check the cause
The status of valve 5 and its operation during system activation
The presence of any mechanical obstruction or damage to valve 5
The integrity of the control signals being sent to valve 5
Repair steps
Clear the error
Use the diagnostic tool to clear the fault code A0D2h.
Monitor the system
Observe the operation of the system after clearing the error to determine if the fault reoccurs.
Replace valve 5
If the error reappears, replace the 5 valve as indicated by the source.
Parts you might need
(0)Get help to fix this fault by requesting a quote