CLAAS A0E6h: Short-circuit on the level of the 6 valve position controller
Issue description
A short-circuit has occurred in the system responsible for controlling the position of the 6 valve. This has caused the 6 valve to return to neutral. The system providing control of the 6 valve position is damaged or short-circuited.
Check the cause
The 6 valve position controller for signs of damage or short-circuiting
The wiring and connections related to the 6 valve position controller
Repair steps
Clear the error
Follow the procedure to clear the fault code as specified in the service manual.
Inspect the 6 valve position controller
Check for visible damage, short-circuiting, or other faults in the 6 valve position controller.
Replace the 6 valve if the error reoccurs
If the error appears again after clearing, replace the 6 valve.
Parts you might need
(0)Get help to fix this fault by requesting a quote