CLAAS A118h: Fault with Valve 7 Not Reaching Float Position
Issue description
The 7 valve does not reach the float position within the set time. This issue may be caused by low oil viscosity due to low temperature, which affects the valve's performance. The 7 valve returns to neutral, and warming up the tractor may resolve the issue temporarily.
Check the cause
Oil temperature and viscosity
Operation of the 7 valve
Tractor warming procedure
Repair steps
Check oil temperature
Ensure the oil is at the recommended operating temperature. Low temperature may reduce oil viscosity and affect valve performance.
Warm up the tractor
Allow the tractor to warm up fully before testing the operation of the 7 valve.
Test the 7 valve
After warming up, test the 7 valve to see if it reaches the float position within the set time.
Replace the 7 valve
If the issue persists after warming up, replace the 7 valve.
Parts you might need