A138h

CLAAS A138h: Valve 8 Returns to Neutral During EEPROM Parameter Save

Issue description

An error occurs when saving parameters to the EEPROM, indicating a memory problem. Valve 8 is returning to neutral during this process. The issue may be resolved by turning off the ignition and waiting 20 seconds. If the error persists, the valve 8 may need to be replaced.

Check the cause

  1. Whether the error reappears after turning off the ignition and waiting 20 seconds

  2. The condition of valve 8 and its connection to the system

Repair steps

  1. Turn off the ignition

    Ensure the ignition is completely turned off.

  2. Wait at least 20 seconds

    Allow the system to reset by waiting for a minimum of 20 seconds.

  3. Restart the system

    Turn the ignition back on and check if the error reappears.

  4. Replace valve 8 if the error persists

    If the error continues after the reset, replace valve 8.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes