A142h
CLAAS A142h: Fault in 8 valve
Issue description
The 8 valve does not return to neutral within the time set. The problem may be linked with oil viscosity (temperature too low) reducing the performance of the 8 valve. Let the tractor warm up and test again.
Check the cause
Oil viscosity
Temperature of the oil
Operation of the 8 valve
Repair steps
Let the tractor warm up
Allow the tractor to reach operating temperature before testing again.
Check oil viscosity
Ensure the oil viscosity is appropriate for the current temperature conditions.
Replace the 8 valve
If the error appears again after warming up and checking oil viscosity, replace the 8 valve.
Parts you might need
(0)Get help to fix this fault by requesting a quote