E-117
CLAAS E-117: Laser Sensor Faulty
Issue description
The system has detected a fault related to the laser sensor. This may affect the accuracy of sensor readings and the proper operation of the machine.
Check the cause
Laser sensor connections
Laser sensor alignment
Laser sensor power supply
Repair steps
Inspect
Check the connections of the laser sensor for looseness, damage, or corrosion.
Verify
Ensure the laser sensor is properly aligned according to the manufacturer's specifications.
Test
Check the power supply to the laser sensor to confirm it is receiving the correct voltage.
Parts you might need