CLAAS E-183 – CAC: Error Study End Stops
Issue description
The control system was unable to learn the lower end stop of a component during the calibration or 'teach-in' process. This fault is primarily associated with the AUTOCONTOUR (CAC) system and indicates that the module did not successfully register the lowest possible position of the front attachment (header). This failure prevents the proper automatic functioning of the header, including height control and ground pressure.
Applies to these machines
5 machines- Jaguar
- Lexion
- Tucano
- Mega
- Dominator
Check the cause
Ensure the machine and header are parked on flat, level ground before attempting calibration
Check for any physical obstructions preventing the header from reaching its lowest possible point
Inspect the single-point hookup/multi-coupler between the combine and the header for poor connections or unseated pins
Examine the header control system wiring harnesses for signs of damage, rubbing, or rodent damage, paying close attention to sensor ground wires
Test sensor voltages with a multimeter while the machine is running. The signal wire (typically Pin B) should fluctuate between 1.0V and 4.0V as the component moves. A static 4.7V indicates the 5V supply and ground wires may be reversed
Inspect sensor arms and linkages to ensure they are not bent, binding, or restricted, and check for internal sensor damage
Repair steps
Repair wiring and connections
Resolve any issues found during diagnostic checks, such as repairing damaged wiring harnesses, fixing bad grounds, or reseating multi-coupler pins.
Attempt recalibration
Re-run the 'learn end stops' or 'teach-in' procedure for the front attachment through the CEBIS or the machine's control terminal. Follow the on-screen prompts to raise and lower the header to its limits until the system confirms success.
Troubleshoot via disconnection
If calibration still fails, unhook the multi-coupler, run the calibration procedure for the feederhouse independently, and then reconnect the header to retry.
Replace faulty sensor
If calibration continues to fail and diagnostics point to a faulty sensor, replace it. Ensure the correct sensor type (analog vs. digital) is used for the specific combine model and year.
Configure control module
If modules have been swapped or upgrade kits installed, have a CLAAS service technician use the CLAAS Diagnostic System (CDS) to ensure the correct module is installed and programmed for the machine.
Parts you might need
(5)- Position/Angle Sensor0000117800
Also listed as 011780.0. Used on various Lexion, Tucano, Mega, Dominator, and Jaguar models.
- Position/Angle Sensor0000117801
Used on various Lexion, Tucano, Mega, Dominator, and Jaguar models.
- AUTOCONTOUR Position Sensor0000110210
Listed for Lexion and Jaguar models.
Sensor Band
0650900Also listed as 650900 or 06509000. Fits standard grain headers on Lexion, Tucano, Mega, and Dominator series.
CAC Electronic Control Module
0139930Example part number for Lexion 480R. Verify correct module by serial number.
Get help to fix this fault by requesting a quote