CLAAS E-190 – KSR: Imbalance Between Left and Right Values
Issue description
The system has detected that the difference between the left and right values is below the acceptable threshold, indicating a problem within the discharge chute control system. This fault is logged when the KSR (Discharge Controller) module detects an insufficient or implausible difference between the target (set) and actual (measured) positions of the upper discharge chute's slewing angle. The system is not seeing the expected change in position from the slewing angle sensor, which may indicate an issue with the measurement or operation of the affected circuit.
Applies to these machines
3 machines- Jaguar 800
- Jaguar 900
- Jaguar Terra Trac
Check the cause
Check for mechanical obstructions to ensure the discharge chute can move freely throughout its entire range of motion and is not impeded by debris.
Inspect the wiring harness and connectors associated with the discharge chute's slewing angle sensor and the KSR module for damage, corrosion, or loose connections (pay close attention to wiring along the discharge chute).
Verify that the KSR module has a stable, correct power supply and a solid ground connection.
Check the signal from the upper discharge chute slewing angle sensor (B79) using diagnostic tools to ensure it is providing a plausible and changing value as the chute is rotated.
Check if the calibration or 'learning' procedure for the discharge chute's end stops has been interrupted or failed.
Repair steps
Address other active faults
Resolve any other active fault codes first, especially those related to the KSR module or other discharge chute sensors, as they may be the root cause of the E-190 fault.
Rectify wiring and connector issues
If any damaged wiring or corroded connectors are found during the diagnostic checks, repair or replace them as necessary. Ensure all connections are clean and secure.
Calibrate the discharge chute
Perform the calibration or 'learning' procedure for the discharge chute end stops as outlined in the machine's operator's manual. This can often resolve issues related to position sensing.
Test and replace the slewing angle sensor
If the fault persists, test the slewing angle sensor's output. If the sensor is faulty or its output is unreliable, replace it.
Inspect the KSR Module
If all other components and wiring have been verified as functional, the KSR module itself may be defective. Have a certified CLAAS technician perform advanced diagnostics to confirm the module is at fault before replacing it.
Contact CLAAS Service
For persistent issues or if specialized diagnostic equipment is required, contact an authorized CLAAS service partner.
Parts you might need
(2)- Angle Sensor (Slewing Angle Sensor)0000118471
Alternative part number 0117800 may also apply. Verify the correct part number for your specific machine's serial number through a CLAAS dealer.
KSR (Discharge Controller) Module
Part numbers for control modules are highly specific to the machine's model and configuration. Obtain the correct part number from a CLAAS dealer using the machine's serial number.
Get help to fix this fault by requesting a quote