E-37

CLAAS E-37 – EFA: Module EFA Defective

Issue description

The EFA (Electro-hydraulic ground drive) module has identified an internal fault, indicating a failure within its power output during operation. This defect in the electronic module that controls the ground drive can trigger an emergency STOP of the machine.

Applies to these machines

  • Jaguar 900-830
  • Jaguar 492

Check the cause

  1. Power cycle the machine (turn off and on) to see if the malfunction clears; if it does not reappear, the module may still be functional

  2. Visually inspect plug connections on the EFA module for secure seating and any signs of corrosion

  3. Inspect the wiring harness and cable connections to the module for any breaks or short circuits

  4. Verify that the module is receiving the correct power supply

Repair steps

  1. Diagnose and clear fault

    Attempt a simple restart of the machine. If the fault does not clear, proceed with diagnosing the module's connections and power supply.

  2. Replace EFA module

    If diagnostic checks do not resolve the issue and the module is confirmed defective, replace the EFA module. Alternatively, specialized electronics repair services may offer repair of the existing module.

  3. Calibrate new module

    After installing a new EFA module, perform a learning or calibration procedure for the ground speed control lever potentiometer and hydraulic flows. A message indicating this requirement will appear and should disappear once the procedure is complete.

Parts you might need

(1)

Get help to fix this fault by requesting a quote

Browse other CLAAS codes