1

Deutz-Fahr 1: Low Air Pressure Behind Filter

Issue description

The air pressure located behind the filter is below the required level. This may affect the proper functioning of the system that relies on this pressure.

Check the cause

  1. The filter itself for blockage or damage

  2. The pressure sensor for correct operation

  3. The piping or connections behind the filter for leaks or disconnections

Repair steps

  1. Inspect

    Check the filter for blockage or damage. Clean or replace if necessary.

  2. Test

    Verify the operation of the pressure sensor using the appropriate diagnostic tools.

  3. Examine

    Look for leaks or disconnections in the piping or connections behind the filter.

Parts you might need