1
Deutz-Fahr 1: Low Air Pressure Behind Filter
Issue description
The air pressure located behind the filter is below the required level. This may affect the proper functioning of the system that relies on this pressure.
Check the cause
The filter itself for blockage or damage
The pressure sensor for correct operation
The piping or connections behind the filter for leaks or disconnections
Repair steps
Inspect
Check the filter for blockage or damage. Clean or replace if necessary.
Test
Verify the operation of the pressure sensor using the appropriate diagnostic tools.
Examine
Look for leaks or disconnections in the piping or connections behind the filter.
Parts you might need
(0)Get help to fix this fault by requesting a quote