Deutz-Fahr 1102 – Engine ECU: SCR Heater Relay Open Circuit
Issue description
This fault code indicates an 'open load' or 'current below normal' on the primary side of the SCR heater relay for the Diesel Exhaust Fluid (DEF) supply line. The engine control unit (ECU) has detected a break in the electrical circuit that controls the relay, meaning it is not sensing the expected electrical load from the relay's control coil. This condition is typically caused by a broken wire, a loose or corroded connection, or a failed relay coil.
Applies to these machines
7 machines- TCD 2.9 L4
- TCD 3.6 L4
- TCD 4.1 L4
- TCD 6.1 L6
- TCD 7.8
- TCD 2012
- TCD 2013
Check the cause
Inspect the wiring harness between the ECU and the SCR heater relay for visible damage, chafing, cuts, or corrosion
Check all related connectors for dirt, oil, or moisture, and ensure connector pins are not bent or pushed out
Inspect the fuse related to the after-treatment system or DEF heater circuit for a blown, cracked, or poorly seated fuse
Locate the specific SCR heater relay for the DEF supply line using the machine's service manual or wiring diagram
Repair steps
Disconnect battery
Disconnect the vehicle's battery before performing any electrical repairs to prevent short circuits.
Test relay circuit continuity
Disconnect the connector from the relay. Use a multimeter to check for continuity on the ground wire for the relay's control circuit and the power supply wire from the ECU. An open circuit (infinite resistance) indicates a break that must be traced and repaired.
Check control voltage
If wiring is intact, reconnect the battery and turn the ignition on. Carefully check for control voltage from the ECU at the relay's connector. Absence of voltage when the heater should be active points to an issue with the ECU or the wiring close to it.
Test the relay
Remove the relay and measure resistance across the primary control coil terminals (typically pins 85 and 86). Infinite resistance indicates a broken coil; near zero indicates an internal short. Apply 12V to the coil to listen for a click and check continuity across the secondary terminals (30 and 87).
Perform active test with diagnostic software
If available, use the Deutz SerDia tool to command the SCR heater relay on. If the relay clicks and activates, the issue may be intermittent or related to the ECU's sensing circuit.
Repair or replace components
Replace the relay if it fails testing. If a broken wire was found, repair it using appropriate connectors and sealing methods to prevent future corrosion.
Parts you might need
(3)- SCR Heater Relay04216031
Listed for Deutz TCD 3.6, TCD 4.1, TCD 6.1, and TCD 7.8 engines
- SCR Heater Relay04219374
Generic Deutz relay
Starter / Heater Relay
01340679Listed as a starter relay but may be used in other applications