Deutz-Fahr 1108 – ECM: Short Circuit in SCR Heater Relay Supply Module or Battery

Issue description

The Engine Control Module (ECM) has detected a short circuit to the positive battery terminal within the electrical circuit for the SCR (AdBlue/DEF) supply module's heating element. To prevent damage, the ECU switches off the power stage for this component. This fault affects the operation of the AdBlue supply module and the electrical system, preventing the system from thawing frozen Diesel Exhaust Fluid (DEF) in cold conditions.

Applies to these machines

  • TCD 2.9 L4
  • TCD 3.6 L4
  • TCD 4.1 L4
  • TCD 6.1 L6
  • TCD 7.8 L6
  • TCD 2012
  • TCD 2013

Check the cause

  1. Disconnect the battery before replacing or inspecting any electrical components

  2. When inspecting connectors, ensure they are clean and free of oil or dirt, which can cause poor connections. Pull on the connector body, not the wires.

  3. Visually inspect the wiring harness leading to the DEF supply module for physical damage, chafing, burnt insulation, or corrosion

  4. Disconnect the electrical connector at the DEF supply module and the corresponding relay. Check for bent or corroded pins, moisture ingress, or loose terminals

  5. Disconnect the harness from both the ECU and the SCR supply module, then use a multimeter to check for continuity between the heater circuit wire and a known good 12V power source (there should be no continuity)

  6. Check the resistance of the heater element within the supply module itself (an open circuit or a dead short indicates a faulty module)

  7. Locate the SCR heater relay and swap it with a known good relay of the same type from a different circuit on the machine to see if the fault follows the relay

Repair steps

  1. Isolate the Fault

    Perform the diagnostic checks listed above to determine if the fault lies in the wiring, the relay, or the DEF supply module itself.

  2. Repair Wiring

    If a damaged or shorted wire is found, repair it according to manufacturer standards or replace the affected section of the harness.

  3. Replace Relay

    If the relay is determined to be faulty, replace it with a new, genuine part.

  4. Replace Supply Module

    If the wiring and relay are confirmed to be in good condition, the internal heating element of the DEF supply module is likely defective. The entire module must be replaced as the heater is typically an integrated component.

  5. Clear Fault Codes

    After the repair is complete, reconnect the battery, turn the ignition on, and use a diagnostic tool to clear the fault code from the ECM's memory.

  6. Verify Repair

    Start the engine and allow it to run, preferably in conditions that would call for DEF heating, to ensure the fault code does not return.

Parts you might need

(7)
  • OEM Deutz part. Common relay used across many Deutz TCD engines.

  • DEF Supply Module (Bosch)

    0-444-042-28R

    Example part number for Deutz TCD 3.6 L4. Always verify correct part number using machine and engine serial numbers.

  • Always verify correct part number using machine and engine serial numbers.

  • Deutz Relay04216031

    Genuine Deutz relay compatible with 2012, 2013, TCD 3.6, TCD 4.1, TCD 6.1, and TCD 7.8 engines.

  • Alternative part number for relay.

  • Deutz Glow/Heater Relay

    04286604

    Alternative part number for glow/heater relay.

  • Alternative part number for relay.

Get help to fix this fault by requesting a quote

Browse other Deutz-Fahr codes