1121

Deutz-Fahr 1121: SCR: DEF Pump Motor Supply Module, Short Circuit to Ground

Issue description

A short circuit to ground has been detected in the DEF Pump Motor Supply Module. This fault indicates an electrical issue within the module that may prevent proper operation of the system.

Check the cause

  1. The wiring and connections of the DEF Pump Motor Supply Module

  2. The integrity of the module's housing and insulation

  3. Potential damage or moisture exposure to the module

Repair steps

  1. Inspect

    Visually inspect the DEF Pump Motor Supply Module for signs of damage, corrosion, or moisture exposure.

  2. Test

    Use a multimeter to test for continuity between the module's circuit and ground to confirm the presence of a short circuit.

  3. Replace

    If a short circuit is confirmed, replace the DEF Pump Motor Supply Module with a new or verified functional unit.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Deutz-Fahr codes