1134

Deutz-Fahr 1134: Exhaust aftertreatment 1 Diesel particulate filter (DPF) Differential pressure sensor - voltage above normal value or short circuit to plus

Issue description

The differential pressure sensor for the Diesel particulate filter in the exhaust aftertreatment system is reporting a voltage that is above the normal value or has a short circuit to plus.

Check the cause

  1. The wiring and connections of the differential pressure sensor

  2. The integrity of the sensor itself

  3. The power supply to the sensor

Repair steps

  1. Inspect

    Inspect the wiring and connections of the differential pressure sensor for damage, corrosion, or loose contacts.

  2. Test

    Test the differential pressure sensor for proper operation and voltage output using a multimeter.

  3. Replace

    If the sensor is faulty or the wiring is damaged, replace the affected component.