1135

Deutz-Fahr 1135: Exhaust aftertreatment 1 Diesel particulate filter (DPF) Differential pressure sensor - Voltage below normal value or short circuit to ground

Issue description

The differential pressure sensor for the Diesel particulate filter in the exhaust aftertreatment system is reporting a voltage below the normal value or has a short circuit to ground. This may affect the proper operation of the exhaust aftertreatment system.

Check the cause

  1. The wiring and connections of the differential pressure sensor

  2. The integrity of the sensor itself

  3. The circuit for the differential pressure sensor

Repair steps

  1. Inspect

    Inspect the wiring and connections of the differential pressure sensor for damage, corrosion, or loose contacts.

  2. Test

    Test the differential pressure sensor for proper operation using the appropriate diagnostic tools.

  3. Replace

    If the sensor is faulty, replace it with a compatible component.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Deutz-Fahr codes