1150

Deutz-Fahr 1150: Exhaust aftertreatment 1 Diesel particulate filter (DPF) Differential pressure sensor - Physical limit value exceeded

Issue description

The differential pressure sensor in the exhaust aftertreatment system for the Diesel particulate filter (DPF) has detected a physical limit value that is exceeded, indicating a potential issue with the sensor or the system it monitors.

Check the cause

  1. The differential pressure sensor for the DPF

  2. The wiring or connections to the differential pressure sensor

  3. The DPF itself for blockage or damage

Repair steps

  1. Inspect

    Inspect the differential pressure sensor for visible damage or wear.

  2. Check

    Check the wiring and connections to the differential pressure sensor for looseness, corrosion, or damage.

  3. Test

    Test the differential pressure sensor according to the service manual procedures.

  4. Examine

    Examine the DPF for signs of blockage, damage, or excessive soot accumulation.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Deutz-Fahr codes