Deutz-Fahr 1194 – ECM: Temperature Sensor Before Turbine Indicates Below Minimum Value
Issue description
The Engine Control Module (ECM) has detected an abnormally low temperature reading from the exhaust gas temperature sensor located before the turbine. This indicates that the sensor is either providing a valid reading that is below the expected normal operating range (FMI 1), or there is an electrical fault such as a short circuit to ground (FMI 4). This condition prevents the ECM from accurately monitoring exhaust temperatures, which can negatively impact engine performance and aftertreatment system functions like DPF regeneration.
Applies to these machines
4 machines- TCD 2.9
- TCD 3.6
- TCD 6.1
- TCD 7.8
Check the cause
Visually inspect the wiring harness and connector for the exhaust gas temperature sensor before the turbine for chafing, melting, corrosion, or loose connections.
Check for a short circuit to ground (especially if FMI 4 is present) by inspecting the wiring for pinching or rubbing against the engine block or chassis.
Perform a sensor resistance test using a multimeter; an open circuit (infinite resistance) or dead short (zero resistance) indicates a faulty sensor.
Perform a voltage test on the harness side with the ignition on to verify the presence of a reference voltage (typically 5V or 8V) and a proper ground return.
Repair steps
Ensure Safety
Turn off the engine and engage the parking brake. Allow the exhaust system to cool completely before beginning work. Disconnect the battery to prevent electrical shorts.
Locate the Sensor
Identify the exhaust gas temperature sensor located in the exhaust manifold or piping before the turbocharger.
Perform Diagnostic Checks
Carry out the visual inspection and electrical tests as described in the diagnostic checks section.
Address Wiring Issues
If any wiring faults are found, repair or replace the damaged section of the harness. Ensure all connections are clean and secure.
Replace the Sensor
If the diagnostic checks confirm the sensor is faulty, unplug the electrical connector. Carefully unscrew the sensor from the exhaust manifold (using penetrating oil if seized). Install the new sensor to the manufacturer's specified torque and reconnect the electrical connector securely.
Clear Fault Codes
Reconnect the battery. Use a diagnostic tool to clear the fault code from the ECM's memory.
Verify the Repair
Start the engine and let it run, monitoring the relevant temperature parameter with a diagnostic tool. Check to ensure the fault code does not reappear.
Parts you might need
(4)- Exhaust Gas Temperature Sensor04216426
Upstream of turbine
- Exhaust Gas Temperature Sensor04210188
Upstream of turbine
- Exhaust Gas Temperature Sensor04212425
Fitment noted for TCD 6.1, TCD 7.8 engines
Exhaust Gas Temperature Sensor
0446-7201Upstream of turbine
Get help to fix this fault by requesting a quote