Deutz-Fahr 1242 – ECM: Actuator Relay 7 Short to Ground
Issue description
The Engine Control Module (ECM) has detected a short circuit to ground or voltage below normal in the circuit designated as Actuator Relay 7. While officially described as a relay fault, real-world diagnostics frequently trace this code to a data error, broken ground, or short in the accelerator pedal position sensor circuit. This fault typically forces the engine into a limp-home mode where it will only idle and fails to respond to accelerator pedal input.
Applies to these machines
2 machines- Machines with Deutz EMR3 and EMR4 engines
- Commercial trucks with ISL engines
Check the cause
Verify the ECM has the correct and latest software calibration, as incorrect calibration can cause erroneous codes
Check for other active fault codes (such as 0132) that may also point to the accelerator position sensor
Visually inspect the wiring harness and connectors leading to the accelerator pedal assembly for damage, chafing, or corrosion
Disconnect the pedal and ECM connectors to check continuity on all wires in the accelerator pedal circuit, paying special attention to ground wires
Check for a short to ground on the accelerator pedal signal and supply wires
Test sensor voltages with the key on: verify stable 5-volt supply and ground, and monitor signal voltages for smooth, predictable changes as the pedal is depressed
Repair steps
Isolate the fault
Based on the diagnostic checks, determine if the fault lies in the wiring, the accelerator pedal assembly, or the ECM.
Repair wiring
If a broken wire, short circuit, or corroded connector is found, repair or replace the affected section of the harness. In one successful repair, a new ground wire was bypassed directly to the pedal connector.
Replace accelerator pedal assembly
If the wiring is confirmed to be intact and the sensor's signal is erratic, the accelerator pedal assembly itself is likely faulty and should be replaced. These sensors are often integrated into the pedal unit and are not serviced separately.
Clear fault codes
After the repair, use a diagnostic tool to clear all active and inactive fault codes from the ECM.
Verify repair
Start the engine and operate the accelerator pedal to ensure the engine now responds correctly and that the fault code does not reappear.
Parts you might need
(2)- Relay01340791
Generic Deutz relay (alternate part number 04216031)
Accelerator Pedal Position Sensor / Throttle Pedal Assembly