1281

Deutz-Fahr 1281: Accelerator Pedal 1 Channel 2 - Voltage Below Normal Value or Short Circuit to Ground

Issue description

The accelerator pedal 1 channel 2 is reporting a voltage that is below the normal value or there is a short circuit to ground. This may affect the proper operation of the machine's speed control system.

Check the cause

  1. The wiring and connections related to the accelerator pedal 1 channel 2

  2. The accelerator pedal 1 channel 2 for physical damage or wear

  3. The circuit for any signs of shorting or grounding

Repair steps

  1. Inspect

    Inspect the wiring and connections of the accelerator pedal 1 channel 2 for damage, wear, or loose connections.

  2. Test

    Test the voltage output of the accelerator pedal 1 channel 2 using a multimeter to confirm it is within the specified range.

  3. Check

    Check the circuit for any signs of shorting or grounding, including damaged insulation or foreign objects.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Deutz-Fahr codes