Deutz-Fahr 150 – EMR3: Above target range with system reaction
Issue description
The engine's electronic control unit has detected that the charge air temperature (intake manifold temperature) exceeds the predefined maximum limit, triggering a protective system reaction. This indicates that the air entering the intake manifold after the turbocharger and charge air cooler is too hot, representing a deviation from expected operational parameters that can lead to reduced engine performance, increased emissions, and potential engine damage.
Applies to these machines
3 machines- TCD 2012
- TCD 2013
- TCD 2015
Check the cause
Verify the fault code is active and note the conditions under which it appeared
Check the charge air cooler (intercooler) for blockages from debris (dirt, leaves) and ensure cooling fins are clean for proper heat dissipation. For marine applications, verify the cooling water intake is not clogged.
Inspect the wiring harness and connectors between the charge air temperature sensor and the EMR3 ECU for damage, corrosion, chafing, loose connections, short circuits, or breaks
Check for a 5-volt reference signal from the ECU at the sensor's electrical connector with the ignition on
Test the charge air temperature sensor (thermistor) by measuring its resistance at ambient temperature, then gently heat it with a heat gun (resistance should decrease smoothly as temperature rises)
Verify that the ECU has the correct and latest calibration, as software updates can sometimes address fault sensitivities
Repair steps
Clean charge air cooler
If the charge air cooler is found to be blocked, clean it thoroughly to restore proper airflow and heat dissipation.
Repair wiring
If any wiring faults are discovered during inspection, repair or replace the damaged section of the harness. Ensure all connections are clean and secure.
Replace the sensor
If diagnostic checks point to a faulty sensor (e.g., incorrect resistance readings, no change with temperature), replace the charge air temperature sensor located in the intake manifold after the turbocharger.
Clear fault codes
Cycle the ignition off, wait for the ECU to fully shut down, and then turn the ignition back on. A diagnostic tool may be required to clear the error memory on some systems.
Verify repair
Operate the machine under the conditions that previously triggered the fault to ensure the repair has been successful and the code does not reappear.
Parts you might need
(7)Combined Boost and Temperature Sensor
003969303Deutz-Fahr OEM part number. Verify fitment using machine serial number.
- Temperature Sensor0118 2701
Listed for various Agrotron models.
- Temperature Sensor0421 3839
Listed for TCD2013 and as a supersession for other numbers.
- Temperature Sensor0421 0196
Listed for TCD 2.9, 3.6, 4.1, 6.1, 7.8 engines.
Temperature Sensor
0421 2750Replaces 04210898, listed for TD 2.9, TCD 3.6.
- Temperature Sensor4258759
Listed for 2011 series engines.
Temperature Sensor
A0041530328Verify fitment by serial number.
Get help to fix this fault by requesting a quote