Deutz-Fahr 1532: NOx Sensor After SCR Catalyst - NOx Value Invalid
Issue description
The NOx sensor located after the SCR catalyst is reporting an invalid NOx value. This may indicate a malfunction in the sensor or an issue with the data it is providing.
Check the cause
The NOx sensor after SCR catalyst
The wiring and connections to the NOx sensor after SCR catalyst
The component identified by this code
Repair steps
Inspect
Inspect the NOx sensor after SCR catalyst for physical damage or contamination.
Check
Check the wiring and connections to the NOx sensor after SCR catalyst for looseness, corrosion, or damage.
Test
Test the NOx sensor after SCR catalyst using the appropriate diagnostic tools to confirm its functionality.
Parts you might need
(0)Get help to fix this fault by requesting a quote