Deutz-Fahr 1560 – ECU: SCR Heating System Failure
Issue description
This fault indicates a failure in the Selective Catalytic Reduction (SCR) heating system, which prevents the Diesel Exhaust Fluid (DEF) or urea solution from freezing in cold weather. Depending on the engine control module, this code signifies either an open circuit or broken wiring for the urea suction line heater relay (EMR4 systems), or an electrical issue such as a critical high output current with the DEF pump heating valve (EDC17 systems).
Applies to these machines
7 machines- TCD 2012
- TCD 2013
- TCD 2015
- TCD 3.6
- TCD 4.1
- TCD 6.1
- TCD 7.8
Check the cause
Use a diagnostic scan tool to read the full SPN/FMI code to determine if the fault is in the relay (SPN 524063 / FMI 5) or the DEF pump heating valve (SPN 5706).
For SPN 524063 (Relay fault): Check after-treatment system fuses and swap the urea suction line heater relay with a known good one.
For SPN 524063 (Relay fault): Visually inspect the wiring harness leading to the SCR suction line heater and relay for damage, rubbing, or corrosion.
For SPN 5706 (Valve fault): Inspect the wiring and connector at the DEF pump heating valve for moisture intrusion or damage.
For SPN 524063 (Relay fault): Test for battery voltage at the relay coil connector, check continuity to ground, and measure the resistance of the heater element (infinite resistance indicates failure).
For SPN 5706 (Valve fault): Check for voltage at the valve connector and measure resistance across the terminals to check for open or short circuits.
For SPN 5706 (Valve fault): Use a bi-directional scan tool to command the DEF pump heating valve to activate and verify its response.
Repair steps
Repair wiring harness
If broken wires or corroded connectors are found during inspection for either fault path, repair or replace the damaged section and ensure secure connections.
Replace heater relay (SPN 524063)
If the relay is confirmed faulty, replace it with a new OEM-specified part matching the original pin configuration and amperage rating.
Replace heated urea suction line (SPN 524063)
If the heater element within the suction line has an open circuit, replace the entire heated line assembly.
Replace DEF pump heating valve (SPN 5706)
If the valve is faulty, replace it. Note that this valve is often integrated into the DEF pump assembly, which may require replacing the entire pump unit.
Clear codes and verify
Clear the fault codes using a diagnostic tool and run the engine or perform a system test to ensure the DEF heating system functions correctly and the code does not return.
Parts you might need
(6)- Relay4216031
Generic relay for SPN 524063. Alternate part numbers include 4219374 and 0421-3435. Must match pin configuration and amperage rating.
- Relay4219374
Alternate relay part number.
Relay
0421-3435Alternate relay part number.
Heated Urea Suction Line
Complete assembly including line and heating element. Source via engine serial number.
- DEF Pump / Heating Valve04609000
Bosch DEF pump assembly for SPN 5706. Alternate part number 4603859.
- DEF Pump / Heating Valve4603859
Alternate Bosch DEF pump assembly.
Get help to fix this fault by requesting a quote