1639

Deutz-Fahr 1639 – SCR Controller: SCR Urea Pump Pressure Build-up Failed

Issue description

The SCR Coordinator has detected that the pressure build-up of the urea (DEF) pump was not successful. The system attempted to build pressure five times, each for 90 seconds, but the target pressure was not achieved. This indicates an issue with the urea pump's ability to achieve the required pressure within the allowed time frame, which can lead to engine derate or a no-start condition.

Applies to these machines

  • 5 Series
  • 6 Series
  • 7 Series
  • TCD 3.6 L4
  • TCD 4.1
  • TCD 6.1
  • Bomag

Check the cause

  1. Verify DEF quality using a refractometer (should be 32.5%) and ensure the DEF tank is not empty

  2. Thoroughly inspect the entire SCR system (lines, fittings, connections) for external leaks or white, crusty crystallized urea

  3. Examine all DEF suction and pressure lines for physical damage, kinks, or restrictions

  4. Check the DEF tank breather for blockages that could create a vacuum and prevent fluid draw

  5. Listen for the DEF pump priming sound when the ignition is turned on to verify basic motor operation

  6. Scan for other active fault codes related to NOx sensors, temperature sensors, or CAN communication

Repair steps

  1. Perform system pressure test

    Use a diagnostic tool (like Deutz SerDia) to command an SCR system pressure test. Monitor live data for a target pressure of approximately 9 bar (130 PSI).

  2. Isolate and test the pump

    If pressure does not build, disconnect the pressure line from the pump outlet, connect a pressure gauge directly to the outlet, and command the pump to run. If it fails to generate 9 bar, the pump is likely faulty.

  3. Inspect dosing module (injector) for blockages

    If the pump builds pressure but the system does not, disconnect the DEF line at the dosing module and check for strong fluid flow. If flow is good, remove the dosing module and clean the nozzle with demineralized water, or replace it if clogged.

  4. Inspect and replace DEF filter

    Disassemble the pump/supply module housing and inspect the internal filter. Replace if dirty or clogged with urea crystals.

  5. Perform electrical checks

    If the pump does not run at all, check the electrical connector for power and ground. Inspect the wiring harness between the ECU and pump module for damage or corrosion.

  6. Component Replacement

    If a component (pump, filter, dosing valve) is identified as faulty, replace it with a genuine OEM part.

  7. Clear faults and reset system

    After repairs, use a diagnostic tool to clear fault code 1639 and perform an SCR system reset or re-learning procedure to restore full engine power.

Parts you might need

(4)
  • Bosch OEM. Alternate potential part numbers: 04609000, 0444042019, 04609002, 04603859. Verify by serial number.

  • Often integrated into the pump/supply module.

  • Verify application; may be listed as a fuel lift pump repair kit by some suppliers.

  • Dosing Module (Injector)

    Replace if cleaning with demineralized water is unsuccessful.

Get help to fix this fault by requesting a quote

Browse other Deutz-Fahr codes