1679

Deutz-Fahr 1679: Timeout of CAN Reception Message for AGR Actuator

Issue description

The system has detected a timeout in the reception of the CAN message for the AGR Actuator. This indicates that the communication between the controller and the AGR Actuator is not functioning properly.

Check the cause

  1. The communication link between the controller and the AGR Actuator

  2. The AGR Actuator itself

  3. The CAN bus wiring and connections

Repair steps

  1. Inspect

    Inspect the CAN bus wiring and connections for the AGR Actuator for any damage, loose connections, or corrosion.

  2. Test

    Test the AGR Actuator for proper functionality using the appropriate diagnostic tools.

  3. Verify

    Verify the communication between the controller and the AGR Actuator using the service manual procedures.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Deutz-Fahr codes