Skip to main content
188

Deutz-Fahr 188: Abnormal Update Rate in Function Mode Control

Issue description

A critical control module has detected a timeout or an abnormal update rate for the 'Function Mode Control' message on the CAN bus. This indicates a communication breakdown where a specific ECU expects regular status updates or commands related to the machine's operational mode, but the messages are missing, delayed, or arriving at an inconsistent rate.

Applies to these machines

  • Agrotron K Series
  • Agrotron M Series
  • Agrotron TTV Series
  • Agrotron M610

Check the cause

  1. Check for other active fault codes using a diagnostic tool like Deutz SerDia, as CAN bus errors are often symptoms of other sensor or power supply issues.

  2. Inspect battery and power supply to ensure stable voltage within the correct range, and check power and ground connections to all relevant ECUs.

  3. Visually inspect the CAN bus wiring harness and connectors for chafing, cuts, corrosion, pinched wires, or moisture, especially at main ECUs and firewall/chassis pass-throughs.

  4. Perform a CAN bus resistance check with the ignition and main power switch completely off by measuring between CAN High and CAN Low. A healthy bus is ~60 Ohms; 120 Ohms indicates a missing terminating resistor or open circuit; significantly lower than 60 Ohms suggests a short or too many resistors; an open-line/infinite reading indicates a break in both wires.

Repair steps

  1. Isolate faulty wiring section

    If the CAN bus resistance check reads 120 Ohms (indicating an open circuit or missing terminating resistor), disconnect ECUs or harness sections one by one and re-measure resistance to locate the fault. Consult the wiring diagram for terminating resistor locations.

  2. Check for shorts to power or ground

    With ignition off, measure CAN High and CAN Low to chassis ground (should be 0V). Turn ignition on and measure again (should average ~2.5V). Repair any wiring showing battery voltage or a direct short to ground.

  3. Verify ECU connections

    If wiring and termination resistance are correct, disconnect the suspect ECU, inspect connector pins for damage, corrosion, or loose fit, and reconnect firmly.

  4. Check software configuration

    Use a dealer-level diagnostic tool to verify software compatibility between ECUs, especially if a module was recently replaced.

  5. Replace ECU

    As a last resort, if all wiring and network tests pass and the fault persists at a single module, replace the ECU. Note that this requires programming to the specific machine.

Parts you might need

(6)
  • CAN Bus Terminating Resistor

    Typically 120-Ohm. Often integrated into a wiring harness plug or within an ECU.

  • Engine Control Unit (ECU) - Bosch EDC16UC40

    0281020069

    Used on TCD 2012 engines. Verify exact part number using machine serial number.

  • Verify exact part number using machine serial number.

  • Engine Control Unit (ECU) - Agrotron M610

    25578-ECU01

    Proprietary number for secondhand ECU on Agrotron M610. Verify exact part number using machine serial number.

  • Wiring Harness

    Specific to machine model and harness section. Repairing existing harness is often more practical.

  • SDF Analyser Diagnostic Tool

    5.9030.997.0

    Official diagnostic tool (Deutz Serdia 2000 also applicable).

Get help to fix this fault by requesting a quote