189

Deutz-Fahr 189: Cable Break or Short Circuit in Input Voltage Circuit

Issue description

The fault code indicates a problem with the input voltage circuit, specifically a cable break or short circuit, or an input voltage that is outside the target range. This issue affects the proper operation of the system connected to switch 1.

Check the cause

  1. Cable integrity for switch 1

  2. Input voltage levels for switch 1

  3. Connections related to switch 1

Repair steps

  1. Inspect the cable for switch 1

    Check for visible damage, breaks, or short circuits in the cable associated with switch 1.

  2. Measure input voltage for switch 1

    Use a multimeter to verify that the input voltage for switch 1 is within the specified range.

  3. Check connections for switch 1

    Ensure all connections related to switch 1 are secure and free from corrosion or looseness.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote