5

Deutz-Fahr 5: Low Voltage or Broken Wire in Circuit 4

Issue description

The system has detected low current or a broken wire in circuit 4. This may be caused by a short circuit to -Ubatt or an issue with the wiring in this circuit.

Check the cause

  1. Circuit 4 wiring for breaks or damage

  2. Connection points in circuit 4

  3. Voltage levels in circuit 4

Repair steps

  1. Inspect

    Inspect the wiring in circuit 4 for breaks, damage, or poor connections.

  2. Test

    Test the voltage in circuit 4 to confirm if it is low or if there is a short circuit to -Ubatt.

  3. Repair

    Repair or replace any damaged wiring or connections found in circuit 4.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Deutz-Fahr codes