Deutz-Fahr 508 – ECM: Pressure after HCI Metering Valve Exceeds Maximum
Issue description
An overpressure condition has been detected in the aftertreatment system's hydrocarbon injection (HCI) circuit. The pressure downstream of the HCI metering valve (DV1) has surpassed the maximum allowed threshold, causing the Engine Control Module (ECM) to immediately halt the DPF active regeneration process to prevent component damage.
Applies to these machines
4 machines- TCD 3.6 L4
- TCD 2.9
- TCD 4.1
- TCD 6.1
Check the cause
Visually inspect HCI fuel lines for kinking, crushing, or external damage that could restrict flow
Examine electrical connectors for the HCI dosing valve and downstream pressure sensor for corrosion, damage, or loose connections
Check for blockages in the HCI injector nozzle (carbon and soot buildup) and the HCI fuel lines
Test the pressure sensor wiring for continuity and check for short circuits to power or ground
Test the HCI Dosing Valve (DV1) wiring for open circuits or shorts
Use a diagnostic tool (e.g., Deutz SerDia or Jaltest) to read live data from the HCI pressure sensor and perform a doser pump override test
Repair steps
Prepare machine
Ensure the engine is off and cooled down. Disconnect the battery and wear appropriate PPE for working with fuel and exhaust components.
Access HCI system
Locate the HCI dosing valve (DV1) and the downstream pressure sensor mounted on the exhaust pipe, upstream of the DOC/DPF assembly.
Clean HCI injector
Disconnect the fuel line and electrical connector, then remove the injector. Clean the nozzle and spray holes of carbon/soot using a soft brush and compressed air. Inspect the mounting port for obstructions.
Clear fuel lines
With the injector removed, blow compressed air through the fuel line leading from the dosing valve to the injector to ensure it is clear of obstructions.
Test pressure sensor
If cleaning does not resolve the issue, check voltage at the sensor's signal wire with key on/engine off. With the line open, the diagnostic tool should read atmospheric pressure. If it reads high, replace the sensor.
Reassemble and test
Reinstall the injector with a new gasket, reconnect all lines and the battery. Clear fault codes, initiate a forced DPF regeneration, and monitor HCI system pressure to ensure normal operation.
Parts you might need
(3)- HCI Dosing Valve / Injector04604141
Deutz DEF Dosing Valve. Alternate Bosch part 0 444 043 034 may apply. Verify with dealer.
- HCI Downstream Pressure Sensor04210195
Listed for TCD 3.6 L4; verify exact application with engine serial number.
Gaskets and Seals
Replace any gaskets or seals removed during repair.
Get help to fix this fault by requesting a quote