Deutz-Fahr 511 – EMR4: Pressure after HCI metering valve (DV 1) minimum value exceeded; shutdown regeneration
Issue description
The Engine Control Unit (EMR4) has detected that the fuel pressure in the line after the HCI dosing valve (DV 1) has fallen below the required minimum level. This valve is responsible for injecting a small amount of fuel (hydrocarbons) into the exhaust stream to assist with the regeneration of the Diesel Particulate Filter (DPF). When the pressure is insufficient, the system shuts down the regeneration process to prevent incomplete cycles or component damage.
Applies to these machines
5 machines- TCD 2.9
- TCD 3.6
- TCD 4.1
- TCD 6.1
- TCD 7.8
Check the cause
Check for related fault codes (508, 514, 515, 502, 504, 506) which may pinpoint specific electrical or sensor issues
Inspect the wiring harness and connectors for the HCI dosing valve (DV1) and the downstream pressure sensor for damage, corrosion, or loose connections
Check the fuel supply lines to the HCI module for blockages, restrictions, or clogged filters
Monitor live data from the HCI downstream pressure sensor using a diagnostic tool to verify plausible readings, and check for voltage supply and ground at the connector with the sensor disconnected
Perform a functional test of the HCI dosing valve by listening for actuation clicks and checking the spray pattern and quantity
Repair steps
Address related fault codes
If codes 508, 514, 515, 502, 504, or 506 are present, diagnose and repair those specific sensor or circuit faults first, as they directly affect the HCI system's operation.
Repair wiring and connectors
If visual inspection reveals damaged wires, corrosion, or loose connections at the HCI dosing valve or pressure sensor, repair or replace the affected harness sections.
Restore fuel supply
Clear any blockages in the fuel lines leading to the HCI dosing valve and replace any clogged fuel filters that might be restricting flow to the module.
Test and replace pressure sensor
With the sensor disconnected, check for proper voltage supply and ground at the connector. If the circuit is good but live data readings remain implausible, replace the HCI downstream pressure sensor.
Test and replace HCI dosing valve
Actuate the valve with a diagnostic tool. If it does not click, or if a quantity test reveals a clogged or partially blocked nozzle with an incorrect spray pattern, replace the HCI dosing valve.
Parts you might need
(7)- HCI Dosing Valve04604141
Potential part number (Bosch). Verify against engine serial number.
HCI Dosing Valve
22391563Listed as a DEF Dosage Valve with cross-references. Verify against engine serial number.
- HCI Downstream Pressure Sensor04217188
Replaces 04216645. Verify against engine serial number.
- HCI Downstream Pressure Sensor04216645
Replaced by 04217188. Verify against engine serial number.
HCI Downstream Pressure Sensor
M4199823Replaces 04199478. Verify against engine serial number.
HCI Downstream Pressure Sensor
04199478Replaced by M4199823. Verify against engine serial number.
- HCI Downstream Pressure Sensor01183692
Verify against engine serial number.
Get help to fix this fault by requesting a quote