511

Deutz-Fahr 511 – EMR4: Pressure after HCI metering valve (DV 1) minimum value exceeded; shutdown regeneration

Issue description

The Engine Control Unit (EMR4) has detected that the fuel pressure in the line after the HCI dosing valve (DV 1) has fallen below the required minimum level. This valve is responsible for injecting a small amount of fuel (hydrocarbons) into the exhaust stream to assist with the regeneration of the Diesel Particulate Filter (DPF). When the pressure is insufficient, the system shuts down the regeneration process to prevent incomplete cycles or component damage.

Applies to these machines

  • TCD 2.9
  • TCD 3.6
  • TCD 4.1
  • TCD 6.1
  • TCD 7.8

Check the cause

  1. Check for related fault codes (508, 514, 515, 502, 504, 506) which may pinpoint specific electrical or sensor issues

  2. Inspect the wiring harness and connectors for the HCI dosing valve (DV1) and the downstream pressure sensor for damage, corrosion, or loose connections

  3. Check the fuel supply lines to the HCI module for blockages, restrictions, or clogged filters

  4. Monitor live data from the HCI downstream pressure sensor using a diagnostic tool to verify plausible readings, and check for voltage supply and ground at the connector with the sensor disconnected

  5. Perform a functional test of the HCI dosing valve by listening for actuation clicks and checking the spray pattern and quantity

Repair steps

  1. Address related fault codes

    If codes 508, 514, 515, 502, 504, or 506 are present, diagnose and repair those specific sensor or circuit faults first, as they directly affect the HCI system's operation.

  2. Repair wiring and connectors

    If visual inspection reveals damaged wires, corrosion, or loose connections at the HCI dosing valve or pressure sensor, repair or replace the affected harness sections.

  3. Restore fuel supply

    Clear any blockages in the fuel lines leading to the HCI dosing valve and replace any clogged fuel filters that might be restricting flow to the module.

  4. Test and replace pressure sensor

    With the sensor disconnected, check for proper voltage supply and ground at the connector. If the circuit is good but live data readings remain implausible, replace the HCI downstream pressure sensor.

  5. Test and replace HCI dosing valve

    Actuate the valve with a diagnostic tool. If it does not click, or if a quantity test reveals a clogged or partially blocked nozzle with an incorrect spray pattern, replace the HCI dosing valve.

Parts you might need

(7)
  • Potential part number (Bosch). Verify against engine serial number.

  • HCI Dosing Valve

    22391563

    Listed as a DEF Dosage Valve with cross-references. Verify against engine serial number.

  • Replaces 04216645. Verify against engine serial number.

  • Replaced by 04217188. Verify against engine serial number.

  • HCI Downstream Pressure Sensor

    M4199823

    Replaces 04199478. Verify against engine serial number.

  • HCI Downstream Pressure Sensor

    04199478

    Replaced by M4199823. Verify against engine serial number.

  • Verify against engine serial number.